{"id":4145,"date":"2022-12-12T15:48:04","date_gmt":"2022-12-12T15:48:04","guid":{"rendered":"https:\/\/wiralabanalitika.com\/?post_type=product&#038;p=4145"},"modified":"2026-04-08T19:57:32","modified_gmt":"2026-04-08T12:57:32","slug":"thermo-scientific-element-2-element-xr-high-resolution-icp-ms","status":"publish","type":"product","link":"https:\/\/wiralabanalitika.com\/en\/product\/thermo-scientific-element-2-element-xr-high-resolution-icp-ms\/","title":{"rendered":"ICP MS Element 2 &#038; Element XR High Resolution"},"content":{"rendered":"<p style=\"text-align: center;\"><b>Thermo Scientific Element 2 &amp; Element XR High Resolution ICP-MS<\/b><\/p>\n<p><span style=\"font-weight: 400;\">The Thermo Scientific\u2122 Element 2\u2122 and Element XR\u2122 High Resolution ICP-MS provide class-leading elimination of interferences for the highest level of confidence. With ultra-sensitive and reliable multi-element analyses at trace-level concentrations, there\u2019s no need for complicated sample preparation and method development.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">What is high resolution (HR) ICP-MS?<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The unequivocal separation of analyte ions from spectral interferences is a prerequisite of reliable and accurate multi-element and isotope analysis. High mass resolution is the universally accepted means to separate spectral interferences. With a visible physical separation between the analytes and the interferences from the matrix, the analyst doesn\u2019t require knowledge of the sample matrix prior to analysis.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">High mass resolution (R = 10,000) takes advantage of slight mass differences to analyze elements in the most challenging sample matrices. Arsenic (75As) in a chlorine matrix is masked by argon chloride (40Ar35Cl, 38Ar37Cl) without using high resolution. Selenium (Se) is another key element that benefits from high resolution in common matrices. Beyond chloride matrices, high resolution is frequently applied to separate oxide, argide and nitride interferents, as well as multiply charged ions.<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Low resolution <\/b><span style=\"font-weight: 400;\">analyzes non-interfered isotopes with the highest sensitivity.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Medium resolution <\/b><span style=\"font-weight: 400;\">guarantees interference-free analysis for most elements in the majority of matrix types.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>High resolution <\/b><span style=\"font-weight: 400;\">provides unequivocal separation of analytes and interferences in the most challenging matrices.<\/span><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><b>Features &amp; Benefits\u00a0<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">High mass resolution: Accurately measure isotope signals separate from spectral interferences and produce clean elemental spectra while retaining flexibility.\u00a0<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Straightforward analytical methods: Providing visual confirmation of accurate measurements.\u00a0<\/span><\/li>\n<\/ul>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Interference removal: no use of reactive gases\u00a0<\/span><\/li>\n<\/ul>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">High sensitivity: Get accurate and precise multi-element analysis down to pg\u00b7L-1 concentrations for all resolutions. The Element XR HR-ICP-MS increases the linear dynamic range by an additional three orders of magnitude for maximum flexibility.\u00a0<\/span><\/li>\n<\/ul>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Ideal for transient multi-elemental signals, such as laser ablation, HPLC, GC, CE, FFF.\u00a0<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">High-precision isotope ratios.\u00a0<\/span><\/li>\n<\/ul>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">An advanced research tool with the reliability and robustness to serve in 24\/7 production control.\u00a0<\/span><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><span style=\"font-weight: 400;\">The Thermo Scientific Element 2 and Element XR High Resolution ICP-MS systems cover the mg\/L to sub pg\/L concentration range\u2014making them especially suitable for semiconductor, geological and material science laboratories. The high-performance ion detection system of the Element XR HR-ICP-MS automatically switches between three detection modes to handle signals ranging from ultra-trace to 100% of the sample matrices. With it you can assess any sample matrix.\u00a0<\/span><\/p>\n<p>&nbsp;<\/p>\n<p><b>Element 2 HR-ICP-MS<\/b><\/p>\n<p><span style=\"font-weight: 400;\">The workhorse for semiconductor applications<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The high performance, double-focusing magnetic sector field Element 2 HR-ICP-MS is optimized for ease-of-use, stability and productivity. Get access to a powerful technique for solving specific problems with excellent sensitivity and signal-to-noise ratio.\u00a0<\/span><\/p>\n<p>&nbsp;<\/p>\n<p><b>Element XR HR-ICP-MS<\/b><\/p>\n<p><span style=\"font-weight: 400;\">The gold standard for full elemental screening in high dynamic range laser ablation and solution work, and for large isotope ratios applications<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The combination of a dual-mode SEM with a Faraday detector increases the linear dynamic range by an additional three orders of magnitude. This enables analysis of any matrix element straight without further dilution or precautions to avoid detector damage from inadvertently measuring high level elements<\/span><\/p>\n<p>&nbsp;<\/p>\n<p><span style=\"font-weight: 400;\">Link to the principle :<\/span><\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/IQLAAEGAAMFABWMAFB#\/IQLAAEGAAMFABWMAFB\"><span style=\"font-weight: 400;\">https:\/\/www.thermofisher.com\/order\/catalog\/product\/IQLAAEGAAMFABWMAFB#\/IQLAAEGAAMFABWMAFB<\/span><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Thermo Scientific Element 2 &amp; Element XR High Resolution ICP-MS The Thermo Scientific\u2122 Element 2\u2122 and Element XR\u2122 High Resolution ICP-MS provide class-leading elimination of interferences for the highest level of confidence. With ultra-sensitive and reliable multi-element analyses at trace-level concentrations, there\u2019s no need for complicated sample preparation and method development. What is high resolution [&hellip;]<\/p>\n","protected":false},"featured_media":4146,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[77,126,76,91],"product_tag":[],"class_list":{"0":"post-4145","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-application","7":"product_cat-environmental","8":"product_cat-product","9":"product_cat-trace-elemental-analysis-system","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.0 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>ICP MS Element 2 &amp; Element XR High Resolution - Wiralab<\/title>\n<meta name=\"description\" content=\"Element 2 and Element XR ICP MS systems cover the mg\/L to sub pg\/L concentration range. Ideal for transient multi-elemental signals, such as laser ablation\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/wiralabanalitika.com\/en\/product\/thermo-scientific-element-2-element-xr-high-resolution-icp-ms\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ICP MS Element 2 &amp; Element XR High Resolution\" \/>\n<meta property=\"og:description\" content=\"Element 2 and Element XR ICP MS systems cover the mg\/L to sub pg\/L concentration range. Ideal for transient multi-elemental signals, such as laser ablation\" \/>\n<meta property=\"og:url\" content=\"https:\/\/wiralabanalitika.com\/en\/product\/thermo-scientific-element-2-element-xr-high-resolution-icp-ms\/\" \/>\n<meta property=\"og:site_name\" content=\"Wiralab\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-08T12:57:32+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/wiralabanalitika.com\/wp-content\/uploads\/2022\/12\/ELEMENT-2-IQLAAEGAAMFABWMAFCjpg-650-transformed.png\" \/>\n\t<meta property=\"og:image:width\" content=\"650\" \/>\n\t<meta property=\"og:image:height\" content=\"542\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/wiralabanalitika.com\\\/en\\\/product\\\/thermo-scientific-element-2-element-xr-high-resolution-icp-ms\\\/\",\"url\":\"https:\\\/\\\/wiralabanalitika.com\\\/en\\\/product\\\/thermo-scientific-element-2-element-xr-high-resolution-icp-ms\\\/\",\"name\":\"ICP MS Element 2 & Element XR High Resolution - Wiralab\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/wiralabanalitika.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/wiralabanalitika.com\\\/en\\\/product\\\/thermo-scientific-element-2-element-xr-high-resolution-icp-ms\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/wiralabanalitika.com\\\/en\\\/product\\\/thermo-scientific-element-2-element-xr-high-resolution-icp-ms\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/wiralabanalitika.com\\\/wp-content\\\/uploads\\\/2022\\\/12\\\/ELEMENT-2-IQLAAEGAAMFABWMAFCjpg-650-transformed.png\",\"datePublished\":\"2022-12-12T15:48:04+00:00\",\"dateModified\":\"2026-04-08T12:57:32+00:00\",\"description\":\"Element 2 and Element XR ICP MS systems cover the mg\\\/L to sub pg\\\/L concentration range. Ideal for transient multi-elemental signals, such as laser ablation\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/wiralabanalitika.com\\\/en\\\/product\\\/thermo-scientific-element-2-element-xr-high-resolution-icp-ms\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/wiralabanalitika.com\\\/en\\\/product\\\/thermo-scientific-element-2-element-xr-high-resolution-icp-ms\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/wiralabanalitika.com\\\/en\\\/product\\\/thermo-scientific-element-2-element-xr-high-resolution-icp-ms\\\/#primaryimage\",\"url\":\"https:\\\/\\\/wiralabanalitika.com\\\/wp-content\\\/uploads\\\/2022\\\/12\\\/ELEMENT-2-IQLAAEGAAMFABWMAFCjpg-650-transformed.png\",\"contentUrl\":\"https:\\\/\\\/wiralabanalitika.com\\\/wp-content\\\/uploads\\\/2022\\\/12\\\/ELEMENT-2-IQLAAEGAAMFABWMAFCjpg-650-transformed.png\",\"width\":650,\"height\":542,\"caption\":\"element icp ms\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/wiralabanalitika.com\\\/en\\\/product\\\/thermo-scientific-element-2-element-xr-high-resolution-icp-ms\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/wiralabanalitika.com\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Privat: Product\",\"item\":\"https:\\\/\\\/wiralabanalitika.com\\\/?page_id=3750\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"ICP MS Element 2 &#038; Element XR High Resolution\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/wiralabanalitika.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/wiralabanalitika.com\\\/en\\\/\",\"name\":\"wiralabanalitika.com\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/wiralabanalitika.com\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/wiralabanalitika.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/wiralabanalitika.com\\\/en\\\/#organization\",\"name\":\"Wiralab Analitika\",\"url\":\"https:\\\/\\\/wiralabanalitika.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/wiralabanalitika.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/wiralabanalitika.com\\\/wp-content\\\/uploads\\\/2022\\\/10\\\/logo-wiralab.webp\",\"contentUrl\":\"https:\\\/\\\/wiralabanalitika.com\\\/wp-content\\\/uploads\\\/2022\\\/10\\\/logo-wiralab.webp\",\"width\":500,\"height\":147,\"caption\":\"Wiralab Analitika\"},\"image\":{\"@id\":\"https:\\\/\\\/wiralabanalitika.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.instagram.com\\\/wiralabanalitika\\\/\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"ICP MS Element 2 & Element XR High Resolution - Wiralab","description":"Element 2 and Element XR ICP MS systems cover the mg\/L to sub pg\/L concentration range. Ideal for transient multi-elemental signals, such as laser ablation","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/wiralabanalitika.com\/en\/product\/thermo-scientific-element-2-element-xr-high-resolution-icp-ms\/","og_locale":"en_US","og_type":"article","og_title":"ICP MS Element 2 & Element XR High Resolution","og_description":"Element 2 and Element XR ICP MS systems cover the mg\/L to sub pg\/L concentration range. Ideal for transient multi-elemental signals, such as laser ablation","og_url":"https:\/\/wiralabanalitika.com\/en\/product\/thermo-scientific-element-2-element-xr-high-resolution-icp-ms\/","og_site_name":"Wiralab","article_modified_time":"2026-04-08T12:57:32+00:00","og_image":[{"width":650,"height":542,"url":"https:\/\/wiralabanalitika.com\/wp-content\/uploads\/2022\/12\/ELEMENT-2-IQLAAEGAAMFABWMAFCjpg-650-transformed.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/wiralabanalitika.com\/en\/product\/thermo-scientific-element-2-element-xr-high-resolution-icp-ms\/","url":"https:\/\/wiralabanalitika.com\/en\/product\/thermo-scientific-element-2-element-xr-high-resolution-icp-ms\/","name":"ICP MS Element 2 & Element XR High Resolution - Wiralab","isPartOf":{"@id":"https:\/\/wiralabanalitika.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/wiralabanalitika.com\/en\/product\/thermo-scientific-element-2-element-xr-high-resolution-icp-ms\/#primaryimage"},"image":{"@id":"https:\/\/wiralabanalitika.com\/en\/product\/thermo-scientific-element-2-element-xr-high-resolution-icp-ms\/#primaryimage"},"thumbnailUrl":"https:\/\/wiralabanalitika.com\/wp-content\/uploads\/2022\/12\/ELEMENT-2-IQLAAEGAAMFABWMAFCjpg-650-transformed.png","datePublished":"2022-12-12T15:48:04+00:00","dateModified":"2026-04-08T12:57:32+00:00","description":"Element 2 and Element XR ICP MS systems cover the mg\/L to sub pg\/L concentration range. Ideal for transient multi-elemental signals, such as laser ablation","breadcrumb":{"@id":"https:\/\/wiralabanalitika.com\/en\/product\/thermo-scientific-element-2-element-xr-high-resolution-icp-ms\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/wiralabanalitika.com\/en\/product\/thermo-scientific-element-2-element-xr-high-resolution-icp-ms\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/wiralabanalitika.com\/en\/product\/thermo-scientific-element-2-element-xr-high-resolution-icp-ms\/#primaryimage","url":"https:\/\/wiralabanalitika.com\/wp-content\/uploads\/2022\/12\/ELEMENT-2-IQLAAEGAAMFABWMAFCjpg-650-transformed.png","contentUrl":"https:\/\/wiralabanalitika.com\/wp-content\/uploads\/2022\/12\/ELEMENT-2-IQLAAEGAAMFABWMAFCjpg-650-transformed.png","width":650,"height":542,"caption":"element icp ms"},{"@type":"BreadcrumbList","@id":"https:\/\/wiralabanalitika.com\/en\/product\/thermo-scientific-element-2-element-xr-high-resolution-icp-ms\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/wiralabanalitika.com\/en\/"},{"@type":"ListItem","position":2,"name":"Privat: Product","item":"https:\/\/wiralabanalitika.com\/?page_id=3750"},{"@type":"ListItem","position":3,"name":"ICP MS Element 2 &#038; Element XR High Resolution"}]},{"@type":"WebSite","@id":"https:\/\/wiralabanalitika.com\/en\/#website","url":"https:\/\/wiralabanalitika.com\/en\/","name":"wiralabanalitika.com","description":"","publisher":{"@id":"https:\/\/wiralabanalitika.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/wiralabanalitika.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/wiralabanalitika.com\/en\/#organization","name":"Wiralab Analitika","url":"https:\/\/wiralabanalitika.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/wiralabanalitika.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/wiralabanalitika.com\/wp-content\/uploads\/2022\/10\/logo-wiralab.webp","contentUrl":"https:\/\/wiralabanalitika.com\/wp-content\/uploads\/2022\/10\/logo-wiralab.webp","width":500,"height":147,"caption":"Wiralab Analitika"},"image":{"@id":"https:\/\/wiralabanalitika.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.instagram.com\/wiralabanalitika\/"]}]}},"_links":{"self":[{"href":"https:\/\/wiralabanalitika.com\/en\/wp-json\/wp\/v2\/product\/4145","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wiralabanalitika.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/wiralabanalitika.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/wiralabanalitika.com\/en\/wp-json\/wp\/v2\/comments?post=4145"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/wiralabanalitika.com\/en\/wp-json\/wp\/v2\/media\/4146"}],"wp:attachment":[{"href":"https:\/\/wiralabanalitika.com\/en\/wp-json\/wp\/v2\/media?parent=4145"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/wiralabanalitika.com\/en\/wp-json\/wp\/v2\/product_brand?post=4145"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/wiralabanalitika.com\/en\/wp-json\/wp\/v2\/product_cat?post=4145"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/wiralabanalitika.com\/en\/wp-json\/wp\/v2\/product_tag?post=4145"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}