High operating temperature compared to competitor columns
Low bleed for mass spectrometry use
Applications:
Fatty Acid Methyl Esters (FAMEs)
FAMEs Cis/Trans Isomers
TRACE GC columns for EPA methods
Low bleed and temperature-stable performance tailored to specific EPA methodologies
TRACE TR-524 and TRACE TR-525 Columns: US EPA Drinking Water Test Methods 524 or 525
TRACE TR-527 Columns: US EPA Drinking Water Test Method 527, features the robust, low-bleed performance required for analysis of pesticides and flame retardants
TRACE TR-8270 Columns: US EPA Solid Waste Test Method 8270
TRACE TR-8095 Columns: US EPA Method 8095 for Explosives Testing featuring high max temperature and low surface activity
Applications:
Volatile Organic Compounds (VOCs)
Pesticides
Flame retardants
Explosives
TRACE Gas Chromatography columns for pesticides
Specifically designed and tested for analysis of pesticides
Low bleed decreases MS contamination
Particularly useful for applications requiring a higher temperature
Column inertness results in minimal peak tailing and decreased breakdown of sensitive samples
Applications:
Organophosphate pesticides
Organochlorine pesticides
Pyrethroid pesticides
Herbicides
Each Phase of Trace GC Columns for Pesticides: TR-Pesticide, TR-Pesticide II, TR-Pesticide III, TR-Pesticide IV.
TRACE Gas Chromatography columns for dioxin and PCB analysis
Designed to meet the requirements of high resolution GC-MS methods
TRACE TR-Dioxin 5MS Columns; Specifically designed for Dioxin and Furan testing
Wide coverage of the 17 congeners with the highest toxicological significance
TRACE TR-PCB 8MS Columns; meets the requirements for HR GC-MS analysis of PCBs
Low bleed
Applications:
Dioxins (PCDDs)
Furans (PCDFs)
PCB congeners
TRACE GC columns for biodiesel analysis
Designed for use in carbon neutral fuels development applications
GC columns designed for specific EN methods and ASTM methods
Specific columns for the determination of methanol, FAMEs or glycerides
Applications:
Biodiesel
ASTM D-6584
EN14214
TRACE Gas Chromatography columns for drugs of abuse
Specifically designed for the analysis of common drugs of abuse
TRACE TR-DoA 5MS Columns; widely used for the analysis and determination of a range of toxicological target compounds including amphetamines, codeine and morphine
TRACE TR-DoA 35MS Columns; the recommended column for use in drug testing labs for the confirmation of THC
Applications:
Amphetamines, codeine and morphine
UltraFast
A significant gain in analysis speed compared to conventional GC procedures is obtained through UltraFast Gas Chromatography. UltraFast GC utilizes short (2-10m) narrow bore capillaries and temperature programming conditions usually faster than 2ยฐC/s. This leads to peak widths in the 50-200ms range. The analysis times are in the range of 1 minute or even less.
Benefits of Thermo Scientificโข UltraFastโข GC columns
Dramatically shorter analysis times โ typically a minute or less
Ideal for applications in petrochemical and environmental markets
Long column lifetimes
TRACE GC UltraFast instrument
Dramatically shorter analysis times
Increase sample throughput by a factor of 20
Lengthen column lifetimes
Applications:
Chemical
Petrochemical
Environmental
Flavors and fragrances
TracePLOT
Providing reproducible analyses of permanent gasses, hydrocarbons and solvents Thermo Scientificโข TracePLOTโข TG-BOND Alumina GC columns:
Na2SO4 and KCl deactivation
Optimized for linear and quantitative analysis of polar unsaturated hydrocarbons
Strong bonding to prevent particle generation suits these columns in valve-switching operations without damage to injection and detection systems from particle release
Columns to which water has adsorbed may be regenerated to restore full efficiency and selectivity
Each column has been tested to ensure proper film thickness (1,3-butadiene), selectivity (propadiene and methyl acetylene), resolution (trans-2-butene and 1-butene) and coating efficiency (1,3-butadiene)
Applications:
C1-C5 hydrocarbons
Unsaturated hydrocarbon isomers
TracePLOT TG-BOND Sieve 5A GC columns
Designed for separation of Ar/O2 and other permanent gasses
Specially designed coating and deactivation procedures for chromatographic efficiency and the integrity of the coating porous layer
Deactivation process yields a sharp peak for CO elution rather than the tailing commonly seen in other columns
High retention of molecular sieve permits separation of permanent gasses at temperatures above ambient
Uniform particles remain adherent to the tubing even following continuous valve-cycling
Applications:
Permanent gasses
Refinery or natural gasses
TracePLOT TG-BOND Q Gas Chromatography Columns
Non-polar columns for oxygenated compounds and solvents
Non-polar 100q% divinyl benzene phase
Particles incorporated into the walls of the tubing for essentially no particle release
Applications:
C1 to C3 isomers and alkanes up to C12
Separation of CO2, methane and O2/N2/CO
Analysis of oxygenated compounds and solvents
TracePLOT TG-BOND Q+ GC columns
Intermediate polarity columns for baseline separation of ethane, ethylene and acetylene
This web-site is really a walk-through you discover the data you wished relating to this and didnโt know who ought to Glimpse here, and youโll absolutely discover it