Liquid Chromatography Accessories

img
img
img
img

Liquid Chromatography Accessories

Liquid Chromatography accessories from Thermo Scientific offers a wide range of accessories that suit your LC needs, ensuring confidence in your analysis and delivery of exceptionally reproducible data and reliable chromatography.

Viper finger-tight fitting

Provides ease of use and dead-volume free plumbing of every conventional HPLC and UHPLC system 

  • Provides zero-dead volume fingertight connections
  • Supports operating pressures up to 1,500 bar (22,000 psi)
  • Available in different lengths: 65mm and from 150 to 950mm in 100mm steps
  • Available in different inner diameters: 0.1mm (0.004 in), 0.13mm (0.005 in) or 0.18mm (0.007 in)
  • Easy to use due to stainless steel or biocompatible MP35Nâ„¢ capillaries (1/32 in OD) and fingertight design
  • Works with virtually any valve and column from any manufacturer
  • Fits narrow connections such as 10-port valves and enables mixed use with different designs

liquid chromatography acccessories thermo scientific

Javelin direct-connection column filters

One-piece filter protects HPLC systems 

  • Direct-connection design for maximum efficiency
  • Replace entire disposable filter unit for easy changes
  • Recommended for use as dedicated filters for a column rather than the HPLC system
  • 1/16in CPI tip attaches directly to HPLC column inlet without tubing or wrenches
  • 0.5μm porosity

liquid cheomatography accessories Javelin thermo

UNIFILTER direct-connection HPLC filter systems

Quickly replaced for minimal down time

  • Replaceable 0.5μm drop-in filter enhances column lifetime and improved performance
  • Holder attached directly to the inlet of your analytical system for maximum convenience

UHPLC filter

Liquid chromatography accessories: column protection for Hypersil GOLD 1.9μm and Syncronis 1.7μm columns without compromising performance 

  • Low volume filter cartridge design
  • Maintain peak shape
  • Minimal efficiency loss through dispersion

aksesoris filter kromatografi

 

PTFE one-piece column connector

Excellent for high-throughput screening and quick connection 

  • Fingertight, leak-free connection of analytical and guard columns with 10- 32 threads
  • Minimizes dead volume
  • Inert and biocompatible material

Solvent filters

  • Efficient draw
  • 100% PTFE polymer, including 2μm filters 
  • Built-in helium sparge port and frit

 

PEEKsil capillary tubing

Excellent chemical compatibility and very low carryover3

  • Precision-bore fused silica tubing coated with 1/16in OD PEEK covering
  • Usable in most standard chromatography systems
  • Withstands high pressures
  • Smooth internal surface for excellent flow characteristics
  • Tubing is stiff: not recommended for uses requiring tubing bends
  • Precut lengths only: cutting in the lab may damage tubing

 

316 stainless steel capillary tubing

Cleaned, polished, passivated and ready-to-use

  • Suitable for ultra high pressure applications
  • Wide chemical compatibility
  • Prefinished, square, burr-free ends and interiors to minimize dead volume connections
  • Not recommended for biological samples
  • Rough internal surface may lead to sample carryover

 

PEEK Capillary Tubing

Pre-cut and color-coded for easy identification and use

  • Broad chemical compatibility
  • Biocompatible
  • Easily cut to desired length
  • Appropriate for many HPLC applications 
  • Resistant to most organic solvents, except for nitric acid, sulfuric acid, dichloromethane, THF and DMSO

liquid chromatography accessories PEEK tubing

 

High pressure stainless steel nuts and ferrules

Accommodate a wide range of configurations

  • Designed for 10-32 port configurations
  • Burr and contaminant free

liquid chromatography accessories nuts thermo scientific

Rheodyne 7725 and 7725i Sample Injectors

Allow continuous flow between the load and inject positions to protect against pressure shock

  • Stainless steel construction
  • Make-Before-Break (MBB) design
  • Can use partial filling for zero sample waste or complete filling for better reproducibility
  • Inject 1μL to 5mL with high accuracy and precision
  • 7725i features a position sensing switch for a reproducible start signal.

Also available are Rheodyne 9725, Rheodyne 9725i, Rheodyne 8125 low-dispersion microscale, Rheodyne 7010, and Rheodyne 9010 injectors.

 

LC Syringes

Supporting manual and automated injections 

  •   LC syringes for manual injection valves

Easy, accurate and reproducible manual injection.

  • Square tip to prevent damage to the injector
  • Wide range of volumes
  • Precision made from borosilicate glass and stainless steel
  • Robust design and easy-to-read markings

HPLC Syringes

  • Instrument specific syringes
  • Luer-Lok syringes ideal for priming
  • Macro volume sampling syringes suitable for liquid or gas samples

aksesoris jarum suntik kromatografi

Thermo Scientificâ„¢ HOT POCKET and COOL POCKET (column temperature controllers)

Wrap-around column temperature control systems

  • Easy to install and use with a variety of column lengths 
  • Dual display of both actual and set point temperature
  • HOT POCKET range from just above ambient to 85°C
  • COOL POCKET range from 5°C to 55°C
  • Explore sample selectivity and stability on both sides of ambient